Ceramic Fiber Insulation Boards

Rigid boards for kiln linings and furnace chambers: standard series from 1100 °C, high-temperature series up to 1750 °C. For furnace builders, cut and machined to drawing.

A fiber board is hard like a wooden board. It can be cut and machined, is easy to install and can face the flame directly. Low heat capacity and low thermal conductivity mean the furnace heats faster and loses less heat.

High-temperature laboratory and sintering furnaces often suffer from chamber cracking, deformation, peeling, powdering, and in the worst case collapse. These problems depend heavily on the quality and purity of the insulation, and on chamber design. Our high-temperature series is made from polycrystalline alumina fiber under strict quality control.

1100–1750 °C
Continuous use, eight grades
0.1%
Shrinkage of 1800M board, 1700 °C × 8 h
up to 87% Al₂O₃
High-temperature series (typical)
To drawing
Cut and machined parts supplied

High-temperature series: 1600 to 1900M

Property16001700M1800M1900M
Continuous use temperature1500 °C1600 °C1700 °C1750 °C
Density (kg/m³)400350400700
Linear shrinkage, 8 h0.1% (1500 °C)0.2% (1600 °C)0.1% (1700 °C)0.3% (1750 °C)
Thermal conductivity, 600 °C (W/m·K)0.140.120.12—
Thermal conductivity, 800 °C (W/m·K)0.170.150.160.11
Thermal conductivity, 1000 °C (W/m·K)0.240.180.190.14
Thermal conductivity, 1200 °C (W/m·K)———0.17
Al₂O₃ (%)64757587
Al₂O₃ + SiO₂ (%)989999.599.5

Size 1000 × 600 mm · thickness 25, 40, 50, 60, 70, 80 mm · pallet and wooden crate.

Standard series: 1260 to 1500

Property1260 (250)1260 (300)14001500 (300)1500 (400)
Use temperature1100 °C1100 °C1300 °C1400 °C1400 °C
Density (kg/m³)250300300300400
Linear shrinkage, 8 h2.5% (1100 °C)1.8% (1100 °C)1.6% (1200 °C)0.6% (1400 °C)0.5% (1400 °C)
Thermal conductivity, 600 °C (W/m·K)0.170.160.120.120.11
Thermal conductivity, 800 °C (W/m·K)0.240.230.150.170.15
Thermal conductivity, 1000 °C (W/m·K)——0.250.220.21
Al₂O₃ (%)4343456262
Al₂O₃ + SiO₂ (%)9898989898
GradeDensity (kg/m³)Size (mm)Thickness (mm)
1260250 / 300 / 3501200 × 1000; 1000 × 60025, 30, 40, 50, 60, 70, 80
1400250 / 300 / 3501200 × 1000; 1000 × 60025, 30, 40, 50, 60, 70, 80
1500300 / 350 / 4001000 × 60025, 40, 50, 60, 70, 80

Typical values (averages), not guaranteed values. Test conditions differ between grades; use the values for selection.

Temperature first, then the job

Pick the grade by the continuous temperature on the hot face. Then decide between board and blanket by what the insulation has to do.

What the insulation has to doBoardBlanket
Form a rigid chamber wall that keeps its shape✓
Be cut or machined to a precise shape✓
Face the flame directly✓
Fit curved or irregular surfaces, or wrap pipes and equipment✓
Seal gaps, doors and openings✓
Be folded into modules for linings✓
Hot face vs. backingHigh grade on the hot face, economical grade behindSame idea

Where it is used

Questions about fiber boards

Which grade do I need?
Start from the continuous temperature on the hot face, then the job the board has to do. Tell us your furnace temperature, atmosphere and where the board goes, and we confirm the grade.
Board or blanket?
Boards are rigid, machinable and keep their shape, which suits chamber walls and parts that face the flame. Blankets are flexible and fit curved shapes, seals and modules. Many linings use both.
Can you supply boards cut to shape?
Yes. Boards can be cut and machined to your drawing.
RELATED

Get a quote for fiber boards

Grade, thickness and quantity are enough for a price. Only your email is required. We usually reply within 1–3 business days.

Not sure which grade fits? Tick the recommendation box and add your furnace details.

Email: sales@youka-tech.com

PRODUCT: CERAMIC FIBER BOARDS

Loading the form…

We use your details only to answer your inquiry. See our Privacy Policy.